VH
a notch. The directional seated valve type VH is suitable for pipe connection. The directional seated valve bank type VHR comprises several valves of type VH that have been clamped together connected in [...] Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Catalogue sheet HAWE Compact - Product range: HAWE Kompakt Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Technical data - [...] Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Catalogue sheet HAWE Compact - Product range: HAWE Kompakt Data sheet Directional seated valve type VH, VHP and VHR: D 7647
VH
a notch. The directional seated valve type VH is suitable for pipe connection. The directional seated valve bank type VHR comprises several valves of type VH that have been clamped together connected in [...] Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Catalogue sheet HAWE Compact - Product range: HAWE Kompakt Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Technical data - [...] Data sheet Directional seated valve type VH, VHP and VHR: D 7647 Catalogue sheet HAWE Compact - Product range: HAWE Kompakt Data sheet Directional seated valve type VH, VHP and VHR: D 7647
Manifold mounting valves
Actuation: Solenoid Hydraulic Pneumatic p max : 400 bar Q max : 15 l/min Directional seated valve type VP VH, VHP, VHR Nomen- clature: Directional seated valve, zero leakage Design: Individual valve for pipe [...] mounting, bankable Actuation: Manual p max : 700 bar Q max : 25 l/min Directional seated valve type VH, VHP and VHR MSV 2/2-way poppet valve type MSV, RSV (size 6) RSV 2/2-way poppet valve type MSV, RSV
Single valves
Actuation: Solenoid p max : 250 bar Q max : 4 l/min Poppet valve type SP 1 in manifold system type SL 1 VH, VHP, VHR Nomen- clature: Directional seated valve, zero leakage Design: Individual valve for pipe [...] mounting, bankable Actuation: Manual p max : 700 bar Q max : 25 l/min Directional seated valve type VH, VHP and VHR VP Nomen- clature: Directional seated valve, zero leakage Design: Manifold mounting Actuation:
Directional seated valve type VH, VHP and VHR
29
107.5 74
Type VH 1 and VH 2 Flow pattern symbols of L and S
Type
d3
d4 13
e2 h2 h3 h4 l3 l4 5 39 10 29 60 44
VH 1 - L, S 19 Plugged with a tapped plug with type VH 1(2)-S
VH 2 - L, S 15.5 15.5 [...] Available for: Switching position
Individual valve type VH (P) 1 and VH 2 and valve banks type VHR 1(2) G E M N D
Individual valve type VH(P)1 and VH 2 H L S
Table 3: Actuation Spring return 1) Switch 2) [...] direction acc. to the resp. symbol
Actuation force VH(R) 1: VH(R) 2: Mass (weight) approx. Max. No. of valve sections VH 1: VH 2: VHP 1: For VHR: VHR 1: VHR 2:
3.2
Hydraulic
Variable displacement axial piston pump type V30D
LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller [...] LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller [...] LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller
HAWE Kompakt - Přehled produktů
7788 Z D 7788 BNG
■ ■ ■
– – – – Sedlový rozváděč typu VH, VHR, VHP
■
VH - 1: 700 VH - 2: 500 VHP - 1: 700 VHR - 1: 700 VHR - 2: 500
VH - 1: 12 VH - 2: 25 VHP - 1: 12 VHR - 1: 12 VHR - 2: 25
D 7647
■
HAWE Kompakt - Ürünler
7788 BNG
■ ■ ■
– – – – Oturtmalı yön denetim valfi Tip VH, VHR, VHP
■
VH - 1: 700 VH - 2: 500 VHP - 1: 700 VHR - 1: 700 VHR - 2: 500
VH - 1: 12 VH - 2: 25 VHP - 1: 12 VHR - 1: 12 VHR - 2: 25
D 7647
■
Directional seated valve type EM and EMP
Table 3 Basic type and size
Basic type and size EMP 21 V EMP 21 V 10 EMP 21 V 15 EMP 21 V 20 EMP 21 VH EMP 31 V EMP 31 V 70 EMP 31 V 80 EMP 31 V 100 EMP 41 V EMP 21 S EMP 21 S 10 EMP 21 S 20 EMP 31 S Note [...] customized 40 throttling character- 40 80 istic (see curves, 70 Chapter 3, 80 "Parameters") 100 Type ..VH with stroke 160 limitation 40 40 With manual 40 emergency actuation 80 (not detailed) (see curves, [...] delivery)
1 2
Manual override for EM(P)...S Line connector can be mounted offset by 90° each
EMP .. VH
SW = a/f
Type EM 1.. EM 2.. EM 3.. EM 4.. EMP 2.. EMP 3.. EMP 4.. Version G WG L
a 36.5 36.5 36