Proportional pressure-reducing valve type FB and KFB
acc. to D 7700 ++
; ; < ;
Pressure reducing valve KFB 2/18 - AE - F
<
<
Prop. directional spool valve bank acc. to D 7700-3 PSL 41/350 - 3 - J 25/16/H - H 63/40/H -E4
6600; D6600; D 6600; D6600; 6600 [...] valves type SKS and SKV acc. to D 5700 ++ or type PSL and PSV acc. to D 7700 ++.
D
ty
HAWE HYDRAULIK SE STREITFELDSTR. 25 • 81673 MÜNCHEN © 1981 by HAWE Hydraulik
pe
D 6600
4/3-way prop.-pressure reducing [...] capacity: Ohmic load = 6 A at 30 V Inductive load = 5 A for 30 V Making contact in both operating pos. (coding L ... L 5) Making contact in operating pos. a (l) (coding G ... G 5) The switch has to be adjusted
Energy pack type IEP
2.1 Cells in series (nominal voltage)
Type IEP 014 Nominal voltage (V) 50,4 Umin (V) 35 Umax (V) 58.8 recommended voltage range (V) 42 to 56
2.2 Cell configuration
Coding CP Description Cell configuration [...] Hydraulik SE
D 6130 - 03-2022 - 1.1
7/14
3.3 Electrical data
Power output
Value Voltage nominal Voltage maximal Voltage minimal Configuration (cells connected in series) Energy 50.4 V 58.8 V 35 V 14S 12.0 [...] switching off. We therefore recommend at least 5 V of voltage. A voltage of 24 V may be exceeded up to 28 V for brief periods of less than 5 seconds only.
8/14
D 6130 - 03-2022 - 1.1
HAWE Hydraulik SE
Start
Solenoid plug with economy circuit type MSD 4 ECO
adjustable economy voltage: D 7832
Directional seated valve type EM and EMP: D 7490/1 ional seated valve type WN and WH: D 7470 A/1 Directional seated valve type G, WG and others: D 7300 Directional seated [...] used for double or reversal lift solenoids MD and MU in accordance with D 7055 or twin solenoids in accordance with D 7785 A.
6/10
D 7833/1 - MSD 4 ECO - 01-2021-1.2
© HAWE Hydraulik SE
3.2 Electrical [...] Start current Holding voltage Economy current UB w UA IA UH IH 19 ... 30 V DC 10 % (supply voltage has to be adequately smoothed) UB - 0.8 V DC max. 1.5 A 0.75...0.79% UB permanently set max. 1.2 A Sustaining
Directional seated valve type BVE
connection Nominal voltage V AC X 12, G 12 1) X 24, G 24
1)
V DC 12 V DC 24 V DC 24 V DC 24 V DC 48 V DC 98 V DC 205 V DC 12 V DC 24 V DC 24 V DC 24 V DC 12 V DC 24 V DC 24 V DC 24 V DC
Protection class (IEC [...] o o
110 V AC 50/60 Hz 230 V AC 50/60 Hz AMP Junior Timer 2-pole DEUTSCH plug (DT 04-2P) M12x1 Bayonet Pa6 Schlemmer ATEX
98 V DC 205 V DC 12 V DC 24 V DC 12 V DC 24 V DC IP 65 24 V DC 24 V DC IP 67 IP [...] 0.33 A --23 W 24 V DC -48 V DC -98 V DC -205 V DC 26.2 W 37.2 W 57 W --26.5 W 32.7 W 60 W 8W 18.6 W 26.1 W 29.9 W ---24.8 W 33 W 62 W --28 W 30.2 W 67 W --24 V DC 48 V DC 98 V DC 205 V DC
X 24/8W, G 24/8W
Directional spool valve bank type SWS
brand G 12 X 12 L 12 12V DC 28 2.34 G 24 X 24 L 24 24V DC 28 1.17 G 24 EX
1)
G 48 X 48 48V DC 28 0.58
G 80 X 80 80V DC 28 0.35
G 98 X 98 2) 98V DC 28 0.28
G 205 X 205 2) 205V DC 50/60Hz 28 0.14 AC-voltage [...] solenoid a and b) (A)
24V DC 23.6 1.0
110V AC 50/60Hz 28 0.28
230V AC 28 0.14
DC-voltage Coding G...
Coding L...
Plug
A DIN 43650 Pg 9 (see also D 7163) Coding G (...V DC) is only available with [...] gized Tool adjustable Tool adjustable EM 21V Idle circulation Manually while enadjustable ergized S 6 and S 7 V 6 and V 7 without Idle circulation valve acc. to D 7490/1 Symbole = ..6 A5 = ..7 A 6 and A 7
HAWE Kompakt - Ürünler
58/26 RZ 6911: 10,7/87,5 RZ 6912: 21,4/87,5 RZ 6914: 42,8/87,5 RZ 6916: 64,2/87,5
Doküman D 6010 D 6010 H D 6910 D 6910 H
Tekil pompa Motor pompa Hidrolik ünite Yüksek verimlilik Kompakt yapı ölçüleri Maks [...] özellikler
■
pmax (bar) 80: 700 125: 1500 160: 1500
Vg maks (cm3/strok) 80: 6,00 125: 28,30 160: 28,30
Doküman D 7280 D 7280 H
Tekil pompa
– Yüksek çalışma basınçları – Patlamaya karşı korumalı sistem ve [...] 350 HD - 20: 220 HD - 30: 150
Vg maks (cm3/strok) H - 16: 6,00 H - 20: 9,40 H - 25: 14,70 HE - 3: 3,00 HE - 4: 4,00 HD - 13: 13,00 HD - 20: 20,00 HD - 30: 30,00 08: 8,3
Doküman D 7147/1
Tek etkili Çift
Valve bank (directional seated valve) type BVH
with 10 m connecting cable
12 V DC 24 V DC 98 V DC 205 V DC 110 V AC 50/60 Hz 230 V AC 50/60 Hz 12 V DC 24 V DC 98 V DC 205 V DC 110 V AC 50/60 Hz 230 V AC 50/60 Hz 24 V DC
250
IP 65
M12x1
250 Circuit [...] class X 12 12 V DC 29.4 W XM 12 12 V DC 26.2 W X 24 24 V DC 27.6 W XM 24 24 V DC 26.5 W M24/8W 24 V DC 8W WG 110 110 V AC 28.6 W WGM 110 110 V AC 24.8 W WG 230 230 V AC 30.2 W WGM 230 230 V AC 28 W
On or [...] connection blocks type AB, -D 6905 AB For combination with compact hydraulic power packs: INKA D 8132-1 HK D 7600-2, D 7600-3, D 7600-4 HKL D 7600-3L KA D 8010, D 8010-4 MPN D 7207 Version for pipe connection
Circuit board for HLU LE-X (E)
connection 24 V DC +/- 10 % (residual ripple < 100 mV) < 50 mA (w/o external switching load) DC < 2.5 V DC
PNP short-circuit-proof - type 3 (24V DC)
TON and TOFF < 500 μs 100 % None up to max. 30 V DC (integral) [...] ty of the system operator.
8/10
D 6052 0003 - 12-2021 - 1.0
HAWE Hydraulik SE
Circuit example
1
Earth
HAWE Hydraulik SE
D 6052 0003 - 12-2021 - 1.0
9/10
D 6052 0003 12-2021-1.0
HAWE Micro [...] Phone +49 89 379100-6000 | info@hawe-microfluid.com | www.hawe.com hawe.com/contact
6052; D6052; D 6052 0003; D6052 0003; 6052; 0003
Montážní návod pro hydraulické čerpadlo ovládané tlakovým vzduchem typu LP
dla typ LP
Dle prospektu D 7280 a D 7280 H
1. Přípoj tlakového vzduchu a hydrauliky
Zprostředkovatel tlaku Náhon a tlak (strana vzduchu) Tlakový vzduch pracující s v obchodě obvyklými udržovatelnými [...] zasunout do vrtání v tělese.
@ Zátky s Cu-těsněním opět ručně pevně dotáhnout.
Liší-li se připojovací závity u A (rozváděč) a L (LP-čerpadlo) od sebe, můžete tyto přizpůsobit v případě potřeby v obchodě obvyklými [...] . 500 m2/s Provozní tlaky pHy viz. D 7280 (H) Udržovací jednotka Pro bezproblémovou přípravu tlakového vzduchu a bezpečnou funkci čerpadel jsou potřebné v obchodě obvyklé udržovatelné přístroje
Y-adapter
resistance Coding Overvoltage category Protection class 30 V AC and 30 V DC 4 A 4 ≥ 10 GΩ A - Standard II IP65 and IP67
HAWE Hydraulik SE
D 6052 0002 - 11-2021 - 1.1
5/7
3
Dimensions
All dimensions [...] Phone +49 89 379100-6000 | info@hawe-microfluid.com | www.hawe.com hawe.com/contact
6052; D6052; D 6052 0002; D6052 0002; 6052; 0002
[...] dimensions in mm, subject to change.
Centre-to-centre distance 12
6/7
D 6052 0002 - 11-2021 - 1.1
HAWE Hydraulik SE
D 6052 0002 11-2021-1.1
HAWE Micro Fluid GmbH Borsigstraße 11 | 93092 Barbing | Germany