Throttle screw type Q, QR and QV
70 75 70 75 100 130 140 250
Q(R, V) 2 S Q(R, V) 2 H Q(R, V) 2 S Q(R, V) 2 H Q(R, V) 3 S Q(R, V) 3 H Q(R, V) 4 S Q(R, V) 4 H Q(R, V) 5 S Q(R, V) 5 H Q(R, V) 6 S Q(R, V) 6 H
1)
#6 #8 # 10 # 12 # 16 # 20 [...] Q(R, V) 2 Q(R, V) 3 Q(R, V) 4 Q(R, V) 5 Q(R, V) 6 Corner valve appr. g 100 140 190 270 Type Q(R, V) 2S Q(R, V) 3 S Q(R, V) 4 S ----with banjo bolt appr. g 50 90 110 Type Q(R, V) 2H Q(R, V) 3 H Q(R, V) 4 [...] Q(R, V) 5 H Q(R, V) 6 H appr. g 40 70 90 130 230 Type Q(R, V) 2 S6 Q(R, V) 2 S8 Q(R, V) 3 S10 Q(R, V) 4 S12 ----Banjo elbow appr. g 100 170 220 Type Q(R, V) 2 H6 Q(R, V) 2 H8 Q(R, V) 3 H10 Q(R, V) 4 H12
Proportional amplifier type EV2D
amplifier type EV2S: D 7818/1 Proportional amplifier type EV1M3: D 7831/2 Proportional amplifier type EV1D: D 7831 D
Application ■ Proportional directional valve type PIH 06: D 6418 ■ Proportional d [...] OUT
HYDRAULIK
EV2D-G
EV2D-EW
114
10/25
D 7821 - 01-2021 - 1.0
HAWE Hydraulik SE
99
LAN IN
EV2D-EC-G
23 19 111
24Vdc ENABLE FAULT
SERVICE
99
74
LAN OUT
HYDRAULIK
EV2D-EC-G
114
HAWE Hydraulik [...] Proportional amplifier type EV2D
Product documentation
Supply voltage UB: Output current Imax: 19 to 30 V DC 4A
D 7821 01-2021 -1.0 en -1.0 en
© by HAWE Hydraulik SE. The reproduction and distribution
Valve control type CAN-IO 14+
type NSWP 2: D 7451 N Variable displacement axial piston pump type V60N: D 7960 N Variable displacement axial piston pump type V30D: D 7960 Variable displacement axial piston pump type V30E: D 7960 E Proportional [...] logical valve control type PLVC 41: D 7845-41 Proportional amplifier type EV2S: D 7818/1 Proportional amplifier type EV1D: D 7831 D Proportional amplifier type EV1M3: D 7831/2
Application
■ ■ ■ ■ ■ ■ ■ [...] Aptiv 211PC249S0033 D-Sub plug DE-9 (CAN bus) D-Sub plug DE-9 (RS232) Magnetic plug by DIN EN 175301-803 IP 20 100…240 V AC, 50…60 Hz 24 V DC Max. 1 A 120 Ω terminal resistor integrated in D-Sub plug R = 10
zpětný ventil typu RC
nebo v hydraulickém systému je nutné zohlednit všechny informace obsažené v této dokumentaci. Filtrování a #istota hydraulické kapaliny Nečistoty v jemné části, jako je např. otěr a prach, nebo v části [...] 12/13
D 6969 R - RC - 11-2014-1.1
© HAWE Hydraulik SE
Další informace
Další provedení
■ ■ ■ ■
Zpětný ventil s clonou typu BC: D 6969 B Zpětný ventil typu RK a RB: D 7445 Zpětný ventil typu RE: D 7555 [...] Hydraulik SE
D 6969 R - RC - 11-2014-1.1
3/13
1
Přehled zpětných ventilů typu RC
Zpětné ventily patří ke skupině uzavíracích ventilů. Uzavírají proud oleje v jednom směru a otevírají ho v opačném směru
Directional seated valve type G with interchangeable solenoid
long, see D 7163
12 V DC 24 V DC 48 V DC 98 V DC 205 V DC 12 V DC 24 V DC 24 V DC 110 V AC / 98 V DC 230 V AC / 205 V DC 12 V DC 24 V DC 12 V DC 24 V DC 12 V DC 24 V DC 24 V DC
NOTICE
X(G)M 12/30W and X(G)M [...] class Contact temperature
12 V DC 26.2 W 2.18 A on:
24 V DC 18.9 W 0.79 A off:
12 V DC 30 W 2.5 A
24 V DC 30 W 1.25 A
48 V DC 26.1 W 0.54 A
98 V DC 24.8 W 0.25 A
205 V DC 28 W 0.14 A
50 ms (G..) [...] ow rate (lpm); Sp ow resistance (bar)
Curve a: P d A and A d R Curve b: P d R Additional elements Check valve
Curve c: P d A(B) Curve d: A(B) d R
Orice
Q ow rate (lpm); Sp ow resistance (bar)
Check valve type CRK, CRB and CRH
are not applied to the valve housings. Flow direction Type CRK: A d B free B d A blocked CRB: A d B blocked B d A free CRH: B d A free A d B blocked with zero leakage in idle position (Z port depressurised) [...] M24x1.5
Counterbore #Bmax 16+0.2 20+0.2 24+0.2 16.5 20.5 24.5
#D 22 24 30 22 24 30
#D1 14.3 18.3 22.3 14.5 18.2 22.5
#D2 11 14 16 ----
#d 8 10 11 11 12 16
t 17 18 21 ----
t1 13 15 16 4 4.5 5.5
t2 22 [...] CSJ: D 7736 Pressure-reducing valve type CDK: D 7745 Pressure-dependent shut-off valve type CDSV: D 7876 Check valve type RK and RB: D 7445 Check valves, type RC: D 6969 R Check valve type RE: D 7555 R
Compact pump type MP
Main 230V 50 Hz : I230V , I400V · 400V 230V 400V 500V
Main 500V 50 Hz : I500V , I400V ·
MPW 22
MPW 12
MPW 24
MPW 14
Version for 1-phase mains
1)
Gear pump
Motor current IM (A) 230V 50 Hz [...] voltage 230/400V 50 Hz (265/460V 60 Hz) Actual mains voltage 400V 60 Hz
Selected pump MP 24 A - H 0,81 pmax = 570 bar 400V pmax , · 570 bar 1.1 · 460V pmax , 450 bar
D 7200 page 7
4. [...] 3 + 400V ! 50 Hz 3 + 230V / 50 Hz 3 + 500V 50 Hz 5) AC-motor 1 + 230V 50 Hz
1) Motors 2) Max. 3)
for other mains voltages and/or mains frequency 60 Hz on enquiry
4) For
permanent load 500V +15%, acc
Motor pump and hydraulic power pack type R and RG
(kW) 0.25 - 1.5 B6 D6 B 13 D 13.1 B 20 D 13.2 D 20 B 30 D 30 D 40 9.2 (6.2) 7631 6010 6011 6012 7631 6010 6011 6012 B 40 D 30 D 40 7631 6010 6011 6012 B 50 D 50.1 7631 6010 6011 6012 B 75 D 50.2 7631 6010 [...] B 40 D 6 to D 40 B 50 to B 400 D 50 to D 250 B 6 to B 40 D 6 to D 40 BF 0 /... BF 1 /... BF 2 /... BF 3 /... B 50 to B 400 D 50 to D 250 B 6 to B 40 D 6 to D 40 BF 4 /... BF 5 /... E /... EF 0 /... EF [...] [m nom. 50% -30 [m abs. Manufacturer’s designation B 6 to B 40 D 6 to D 40 B 50 to B 400 D 50 to D 250 B 6 to B 40 D 6 to D 40 AF 0 /... AF 1 /... AF 2 /... AF 3 /... B 50 to B 400 D 50 to D 250 B 6 to B
ROVO robot platform (3rd generation)
SE
D 6140 - 10-2022 - 1.0
5/11
2.3 Accessories
Coding External power supply Description
■ ■ ■ ■
12 V 450 W or 830 W 24 V 450 W or 830 W 48 V 830 W 96 V high-voltage supply 3 kW (1-phase 230 V) 5 kW [...] electric drives, air-cooled 100.8 V
■ ■ ■
100.8 V lithium-ion exchangeable rechargeable battery 12 V backup battery Integral battery management system (BMS) 100.8 V 117.6 V 70 V 9.4 kWh 93.6 Ah 220 A 320 A [...] information
10/11
D 6140 - 10-2022 - 1.0
HAWE Hydraulik SE
References
Other products ■ Energy pack type IEP: D 6130 ■ Energy pack type EP 94: M 6130 EP 94 ■ Type EP 88 battery pack
D 6140 10-2022-1.0
Hydraulic power pack type R and RG
, see D 6010 H
D(B) 13, D(B) 20 175 103 108 105 181
Version with more than two pressure ports Type D 6 and B 6 Type D 13.. and D 20 as well as B 13 and B 20
Type D 30 and D 40 as well as B 30 and B [...] 160 and D 100.2 B 250 and D 250.1 B 400 and D 250.2 B 100 and D 100.1 B 160 and D 100.2 B 250 and D 250.1 B 400 and D 250.2
2.4
Pressure limitation with power packs B(D) 6 to B(D) 40
The tank and cover [...] a a a a a a a a a a
B 13 and D 13.1 4) B 20 and D 13.2 4) B 30, B 40 and D 30 B 50 and D 50.1 B 75 and D 50.2
4)
see above example
a - a a - a a a a
d a c a a
3)
max. 4 ports
a