Hand pump type CH
(600 bar)
HAWE Hydraulik SE
D 7147 CH - 09-2022 - 1.0
7/14
Weight
Type CH 08 P CH 08 P-S CH 08 G-AS CH 08 PG CH 08 PG-S = 2.3 kg = 2.4 kg = 3.0 kg = 1.7 kg = 1.8 kg
8/14
D 7147 CH - 09-2022 - 1.0
HAWE [...] dirt).
HAWE Hydraulik SE
D 7147 CH - 09-2022 - 1.0
13/14
References
Additional versions ■ Manual pump type H, HD and HE: D 7147/1 ■ Compact hydraulic power pack type CPU: D 8010 CPU (The CH hand pump [...] | Germany Phone +49 89 379100-1000 | info@hawe.de | www.hawe.com hawe.com/contact
7147; D7147; D 7147 CH; D7147 CH; 7147; CH
Compact hydraulic power pack type HKF 4 with frequency converter
switches: Coding T, T60 Coding S, D S (N/O contact) D (N/C contact) Coding S-T Coding DT
Coding D-T
Coding D-D
1. Switching point 2. Switching point
© HAWE Hydraulik SE
D 7600-4FU - 02-2019-1.0
13/26 [...] appendix II, No.1 B
Compact power pack type HK(L) and HKF acc. to our documentation D 7600-2, D 7600-3, D 7600-3L, D 7600-4 and D 7600-4FU (latest release)
is an incomplete machine (acc. to article 2g), which [...] and KAW size 2: D 8010 Compact hydraulic power pack type KA and KAW size 4: D 8010-4 Compact hydraulic power pack type HC and HCW: D 7900 Compact hydraulic power pack type MPN and MPNW: D 7207 Direct current
Operating instructions for HAWE devices for designated use in potentially explosive atmospheres
O II 2D Ex tb IIIC T135°C Db Ex db IIB T4 Gb Ex tb IIIC T135°C Db NEC 500, CEC: ■ Class I, Div. 1, Grp B, C, D T4 NEC 500: ■ Class II/III, Div. 1, Grp E, F, G T4 NEC 505: ■ Class I, Zone 1, AEx d, IIB T4 Gb [...] IECEx International NEC
O II 2G Ex db IIB+H2 T4 Gb O II 2D Ex tb IIIC T135°C Db Ex db IIB+H2 T4 Gb Ex tb IIIC T135°C Db Class I Div. 1 Gp B,C,D T4 Class II Div. 1 Gp E,F,G T4 Class III Div. 1 & 2 Class [...] ATEX EU IECEx International NEC
O II 2G Ex db IIB T4 Gb O II 2D Ex tb IIIC T135°C Db Ex db IIB T4 Gb Ex tb IIIC T135°C Db Class I Div. 1 Gp C,D T4 Class II Div. 1 Gp E,F,G T4 Class III Div. 1 & 2 Class I
Assembly instructions for compact hydraulic power pack type KA and KAW
example. KA 24 KA 28 1 22 S L1 KS KTF E/ P/ H 1.81 HZ 0.59/8.8 - A1/280 - ... - FSR-24V - 3x400 V 50 Hz - 3x400 V 50 Hz
/24 V DC
- G 1/2 x 300 Oil drain hose
Motor voltage Fan Motor voltage Fan (on side) [...] ................... 30 Connecting the electric drive............................................................................................................................. 30 Connections on terminal [...] g. hydraulic accumulator, lter etc. Explanations Document Manufacturer’s operating instructions D 8010 D 5488/1 Manufacturer’s operating instructions "Declaration of incorporation acc. to Machinery Directive"
Manual - Proportional amplifier type EV2S-CAN
the power supply voltage and also voltage inputs like 0-5V or 0-10V. Analog input 2 is able to measure also negative input voltages, e.g. ±10V. It is able to do a differential measurement, between its [...] . . . . . . . . . . . . . . . . . . . . . . . . 30 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Typical use cases . . . . . . . . . . . . . . . [...] a 0-10V input signal for single coil applications . . . . . . . . . . . . 20 Interpretation of a 4-20mA input signal for single coil applications . . . . . . . . . . . 20 Interpretation of a 0-10V input
Battery pack type IEP
1.3 Applicable documents
Standards 2014/35/EU 2014/30/EU Designation Low Voltage Directive EMC Directive The protective objectives of DIRECTIVE 2014/30/EU are achieved by explicit application of EN 60204-1 [...] life performance.
■
IEP 014-CP: Set to 3.98 V per cell. This guarantees a higher number of cycles. If desired the charge cut-off voltage can be raised to 4.20 V, which creates a penalty against the achievable [...] 60204-1, section 4.4.2 Electromagnetic Compatibility (EMC).
Documents D 6130 Data sheet battery pack type IEP
HAWE Hydraulik SE
B 6130 - 04-2023 - 1.1 en
5/39
2
For your safety
The product is built
Manual - Valve control type CAN-IO 14+
2014-04-02 2014-04-22 2014-04-29 2014-04-30 2014-05-27 2014-06-27 2014-07-23 2014-10-06 2015-10-06 2016-05-06 2016-07-27 2016-10-04 2017-03-14 2017-05-30 2017-10-30 2017-11-30 2018-03-14 2019-04-04 Content of [...] be set to enable . . . . . 58 3.29 Joystick with two signals 0. . . 5V at AI0/1 and switches AI2,3 define Output 0/1 . . . . 58 3.30 MOM Switch AI1 defines Output 0 . . . . . . . . . . . . . . . . . . . [...] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Setpoints forwarded to PSL-CAN acc. D7700-2: (>Vers 3.05) . . . . . . . . . . . . . . . 52 Override/Enable . . . . . . . . . . . . . . .
Documentation PLVC
. . 30 With an Intact Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Damaged Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Mechanical [...] . . . . . . . . . . . . . . . . . . . . . . . . . 30 Attaching the Base Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Clamp Contacts . . . . . . . . . . . . . . . . . [...] . . . 344 Valve Nodes as PSL-CAN for PLVC Control Modules . . . . . . . . . . . . . . . . . . 347
V.
14. 14.1. 14.2. 14.3. 14.4. 14.5. 14.6. 14.7. 14.8. 14.9. 14.10. 14.11. 14.12. 14.13. 14.14.
Tips