A distinction is made between:
pressure-controlled:
Area between minimum and maximum flow rate as a function of the pressure difference (inlet pressure minus outlet pressure): Q = f (p) under stated test conditions.
temperature-controlled:
Range between the minimum and maximum flow rate as a factor of the temperature of the hydraulic fluid at a constant pressure difference: Q = f (t , p = const.) under stated test conditions.