Hydraulic consumer
Represents in the function group for a hydraulic drive the component (cylinder, motor) in which the hydraulic energy is converted into mechanical energy.
Rise time
Time that a parameter requires to increase from a specific lower value to a specific higher value.
Rise response
Change in the output signal over time for a rising function with a pre-defined rate of change on the input signal. To depict this situation the output signal xa can be plotted in relation to the rate
Minimum cross section for control flow
Equivalent cross-section that the source controlling the related element must have to be able to deliver the minimum control flow.
Control card
Printed circuit board (PCB) with electronic controller - at European manufacturers mostly in the eurocard format - that is used to control a proportional valve or servo valve. The control card is most
Minimum control flow
Flow rate that the source controlling an element must provide to control the element reliably.
Response time of a cylinder
Time that is measured between the hydraulic fluid entering the cylinder and the start of the piston movement.
Response value
With analogue measuring procedures the response value is the smallest value for a change in the input variable that, starting from the zero point, causes a clearly identifiable change in the output va
Response threshold
Minimum signal variable that is required on the input to a device to change the output variable.
Response sensitivity
Change in the input signal that is necessary to generate a measurable change in the output signal, if the input signal is changed from a static point in the same direction in which the static point wa