Centralised hydraulic oil supply
A series of different consumers is supplied with hydraulic oil from a central drive station (Figure Z 4a) and (Figure Z 4b). As a result, the total performance to be installed does not need to be spec
Timing control
Control in which the reference variable (n) is delivered by a time-dependent programmer . The programmer can be started by a trigger signal (DIN 19 226).
Time-continuous signal
The signal parameter is defined at any point in the duration of the signal (DIN 19 225).
Time constant
Also called the delay time. It is the time, which the output signal of a 1st order delay element requires to reach 63% of the end value. After 3 · T 95 % and at 5 · T almost 100 % of the end value (Fi
Primary actuation
Option to confirm on a device which takes precedence over the other actuation.
Pilot-controlled valves
Valves with a large nominal width (generally greater than the nominal size 16 or sometimes at nominal size 10 or nominal size 6) and therefore with large actuation forces are pilot-controlled by a sma
Pre-charged oil tank
If the oil in a system is intended to remain practically free from air (e.g. in aircraft hydraulics), the entire circuit must be placed under a slight excess pressure (approx. 0.3-0.4 bar). This happe
Pre-charge container
Low-pressure accumulator (3 to 6 bar) to create a traverse speed in the case of large cylinders, for which there is no more pump for rapid traverse . The pre-charge container is refilled with the refl