Volumetric losses
Arise with all displacement machines as the sum of the leaked oil and compression losses. The pressurised chambers in the devices are sealed off from moving components by mating surfaces and rods. The
Stiffness of actuators
The spring effect of the compressed oil column is decisive for the stiffness of actuators. The dimensions of the actuator also play a role. In the case of a hydraulic motor with a high response propor
Controller structures
Construction of a It may be simple – e.g. P-controller or PT1 controller, etc. – or complex (e.g. state control or adaptive control ).
Control amplifier
Activation amplifier for high response proportional valves ( Figure R 19 ). has largely the same functionality as proportional amplifiers for position-regulated proportional directional valves.
Break away pressure
Pressure required to overcome the stiction under defined conditions (DIN 24 312)
Hydrostatic laws
The technical processes in hydraulics are essentially based on the following basic laws of physics: Pascal's law : (Blaise Pascal, 1623—1662). Every force acting on a stationary fluid generates a pres
Electro-hydraulic linear amplifier
Stepper motor-operated or less frequently DC motor-operated hydraulic cylinder with integrated control unit ( following control valve ) and mechanical feedback via spindle or toothed rack that can be
External fluid admission
On valve-controlled radial piston machines on which the pistons are supported on an eccentric element (internal support) the supply of the hydraulic fluid on motors is from the exterior onto the pisto
Flange mounted filter
Filter that is formed as an intermediate plate filter or as a flange mounted filter for attachment to the tank or to control blocks . Flange mounted filters are often used before high response proport