Controller structures
Construction of a It may be simple – e.g. P-controller or PT1 controller, etc. – or complex (e.g. state control or adaptive control ).
Class of accuracy
the actual value or of the end value. Example for electrical measuring instruments: 0.1 — 0.2 — 0.5 — 1 — 1.5 — 2 (VDI 2600).
Contact ratio t p
seals within a limit the surface area moved past the surface should have a contacting ratio of at least 50% (1:2).
Noise level L p
Logarithmic sound pressure p, in relation to the sound pressure p o The reference sound pressure p O (pO = 20 μPa) is equal to the noise pressure of the human hearing threshold level at 1000 Hz in dB. The noise [...] can also be determined for certain frequency bands. The noise level states how much noise is present at the respective location. It gets smaller as the distance from the source of the noise increases, therefore [...] therefore the measuring distance must always be stated along with the noise level (for humans: normally 1 m). In practice, calculating the noise level of a deployed machine is problematic: cf. Noise measurement
Hydrostatic power P h
effective hydrostatic power at the output side is determined by the effective flow rate and the effective pressure difference. Refers to the power produced by a flow rate Q at a pressure difference Δp: The [...] The theoretical hydrostatic power at the output side ignores any volumetric losses and hydromechanical losses.
Pressure-flow rate (p/Q) characteristic
continuously adjustable directional valves : The flow depends on the magnitude of the pressure drop assumed at the control edges as well as the magnitude of the opening cross-section and with it the swing on the [...] the pressure rise with increasing flow rate: the harder the spring, the higher the pressure climbs at Q max. Here pilot-controlled pressure valves are better (Figure D 83) .
Piston
medium acts and thereby generates a compressive force. F K = p 1 · A K — p 2 · A R Since friction occurs during the piston movement (particularly at the seals ), the force given off is smaller (≤ nominal force [...] piston is set down on the diameter of the piston rod (area A St). This results in an annular area A R, which is also the return area for differential cylinders ( ratio of piston areas α). With single-acting
Pressure-flow (p-Q) control of a pump
Controller combination in which the setpoint Q for the flow rate controller and the setpoint p for the pressure controller are pre-defined electrically on proportional valves. In this way the performance [...] system and in this way the losses with closed loads significantly reduced by operating the flow rate at a low pressure, the so-called standby pressure (approx. 15...20 bar) (Figure D 74) .
Surface roughness
or R max — does not say anything about whether the profile is "open" — which is not good for seals ( Figure O 1 a ) — or "closed" — and therefore good for seals ( b ) — the R t value for the profile must [...] an R a of 0.5 to 1.5 μm is often used. However, in order to minimise the debris from seals on moving surfaces, the R a for these must not exceed 0.25 μm. However, since the R a value — just like R t or
Labyrinth seal
by the contour of the gap assuming a meandering or zigzag pattern ( Figure L 1 ). Labyrinth seals — mainly filled with grease — are used in hydraulics to protect roller bearings in heavily contaminated