Partner we build on
Partner brands HAWE HİDROLİK VE OTOMASYON SİSTEMLERİ A.Ş. cooperates with well-known partners. Thus, we can offer Turkish customers an even broader product selection beyond the HAWE Hydraulik portfolio. Our
CAN-BUS
possible to connect 32, 64 or up to 128 nodes per CAN bus line. The data transmission is done via two wires, which are called CAN_High and CAN_Low. A CAN network must be assigned an identical transmission [...] analog and digital signal lines, the CAN bus uses a two-wire cable for digital data transmission. System components such as control devices , sensors and actuators can be connected to this cable either directly [...] message. All nodes in the CAN network continuously listen for messages and, on receipt of a message, check whether the data is relevant for them using the identifier. Messages can thus be received and evaluated
Control with replaceable ROM
g, can only be changed by mechanical action in the controller (DIN 19 237). The control with replaceable ROM can be equipped with memory that can be altered (read-only memory with content that can be changed
Sequence diagram
working cycle on hydraulic drives. This can be a position-(stroke)-time diagram on which the times when the drive is moving and stationary can be seen. However, it can also be a stroke-velocity diagram (Figure [...] (Figure A 1) from which the piston velocity in the individual phases of the movement can be seen (including, e.g., the acceleration and deceleration ramps on the usage of proportional valves ).
Twin filter
Combination of two filters with a control unit so that the entire flow rate can be passed through one of the two filters while the other can be cleaned. (Figure D 32)
End position damping
used to reduce the speed of a piston before the end of its stroke. The damping can be mechanical or using a fluid; a choice can be made between fixed or adjustable ( Damping of cylinder motion ).
Supporting ring
in its installation nut. Supporting rings are made primarily of elastic materials and can be loose in the seal or can be vulcanised into the seal ( Figure S 109 ).
Code
into a different form while maintaining the information content. A code can also be a code for an agreed character set that can be used for calculations in a computer system.
Sources of error in measuring instruments
addition, there can be external effects such as temperature, humidity, position, acceleration among others as well as interfering electric fields. Finally incorrect attachment or handling can cause errors
Reprogrammable control
Hard-wired control, in which program changes are provided for and can be performed in a simple manner. These are controls whose program can be changed, for example by reconnecting lines, changing or replacing