Sampling transfer elements
Transfer elements that measure and process the values for continuous variables at discrete times (E DIN 19 226, Part 2).
Blow-off pressure
Response pressure (DIN 24 312)
Circulation index U
Parameter to determine the minimum oil volume of a container, which relates to the flow rate Q of the pump per minute: The size of U depends on the operating mode and fluctuates between 6 in the case
Bent axis machine
Axial piston machine ( Axial piston pump or Hydraulic motor ), in which the cylinder block is turned by a drive flange connected to the drive shaft via the piston rods. The cylinder block is guided us
Flow sensor with oval rotor assembly
Volume counter (not a flow rate counter !) based on two oval rotors with special teeth which cause the fluid flow to rotate ( Figure O 12 ). The flow sensor with oval rotor assembly operates with grea
Flapper-nozzle system
Hydraulic pilot stage in continuously adjustable valves for converting the mechanical output signal from the electrical input stage into an amplified hydraulic signal (Figure D 87) . Armature and flap
Alphanumeric
Refers to a character set that comprises as a minimum the decimal numbers and letters. It is useful to define the scope of the alphanumeric character set in the specific case (EDIN 44 300 part 2).
Additive (for lubricants)
Chemical additive that changes the existing characteristics of a fluid or adds new characteristics (CETOP RP 100). The natural substance mineral oil is lacking a series of characteristics for its task